Aiphone JA-2MECD Especificaciones Pagina 71

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 116
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 70
66
2
1
3
4
+
+
5
6
7
8
DB
P1
P2
P3
DA
11
R
E
1
E
1
E
2
C
3
4
+
5
6
7
8
9
P1
P2
K9
K10
P3
P1
P2
P3
P1
P2
P3
P1
P2
P3
10
1
L
R
YY
E
C
1
3
4
+
5
6
7
8
9
K9
K10
10
2
L
R
Y
E
2
1
C
4
+
5
6
7
8
9
K9
K10
10
3
L
R
Y
E
2
1
3
C
+
5
6
7
8
9
K9
K10
10
4
L
R
Y
E
LEF-10S LEF-10S LEF-10S LEF-10S
BG-10C
3
3
22 22 22
18
LE-D
LE-D
M
M
H
Q
Q
T
YL
BK
Intermixed configuration
3 wires per sub. Run 3 wires to subs individually, or use multi-conductor cable to
wire multiple subs (2 common + 1 per sub).
l LE-D call-in chimes on LEF stations.
l Only LEF-10S station can transmit all call.
l Match door release control terminals (Kn) with door selector #10 with K10, #9
with K9.
Remove a shorting link on LE subs.
*Not available in Europe, Australia,
nor New Zealand
T : PS-1225S, PS1225UL H : AC transformer Q : RY-PA
Wiring
Power source 12V DC, 300mA per LEF station.
Power supply PS-1225S, PS-1225UL
Communication Sub calls in w/(chime) tone & LED, 20 sec.
Depress the LED lit selector button. Use
TALK/LISTEN switch. Master calls in w/tone or
voice (no LED lit). Reply hands-free. To call,
depress a selector, and call by voice or tone.
Door release Contact: 30V DC, 0.1A (resistance load).
Selector switch Contact: 12V DC, 30mA.
Wiring
5 wires common + no .LEF (& subs) (all-master system)
2 wires per sub (single-master system).
* E to - link remains attached.
LE subs: 3 wires with the link removed (when intermixed)
Distance Farthest LEFs 200m(0.65mma)
300m(0.8mma)
Specifications (LEF)
LEF-3 LEF-5, 10, 10S
53.5
180
143
206
190
55
Unit dimensions
BG-10C
All call, chime & music
adaptor
m P.69
LEF-20(S)*, 20-call master (photo)
LEF-30(S)*, 30-call master
LEF-40(S)*, 40-call master
All call, music & chime
Electric door
strike
(locally available)
RY-PA
Door release relay
m
P.104
LEW-10
LEF-10 terminal
box
LEW-10S
LEF-10S terminal
box
LEW-5
LEF-5 terminal
box
Electric door
strike
Electric door
strike
LE-DA
Sub station
m P.69
LE-AN
Privacy sub
m P.69
LE-A
Sub station
m P.69
LE-D
Sub station
m P.69
Door station Room sub station
LE-AN3
3-call privacy sub
LE-A3
3-call sub
LE-A, AN
131
160
51
LE-A3, AN3
53.5
180
143
BG-10C
250
77
165
Power source 12V DC, 2.5A (music max. output).
1.5A(music, chime & all call). 0.1A standby
All call transmit From LEF-3C, 5C, 10C & LEF-1C and LEF-10S
All call receive All LEF master station, and LE-C, CN
Chime tone transmit AUX R, E and AUX L, E
Controls Music on/off. 11 selector switches of music &
chime, chime only or off.
Wiring 19 wires max. BG-10C to LEF-10C.
3 wires to each LE-D, DA.
Distance BG-10C to LEF-C 150m(0.65mma).
230m(0.8mma)
LE-D/DA to BG-10C 200m(0.65mma).
300m(0.8mma).
Specifications (BG-10C)
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Lineup
Vista de pagina 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 115 116

Comentarios a estos manuales

Sin comentarios