TB-AD1, AD10 [TC-M]
MP-1S, MP-3S
NEM-nA/C, NEM-n/C
VC-nM, VCH [VC-K]
AT-406
MC-60/4A
AT-206 [AT-306x3]
TC-M [TB-SE]
TD-1H, TD-3H, TD-6H
TD-12H, TD-24H
TD-6Z, TD-12Z
C-123L/A
IE-1GD(U) [IEH-1CD]
IE-2AD(U) [IEH-1CD]
IE-2A2D(U) [IEH-1C2D]
TCS-MH
IE-1AD(U) [IF-DA]
IE-1GD(U) [IF-DA]
IE-2AD(U) [IF-DA], IE-2A2D(U)
DE-UR [IF-DA]
AP-1M/A, AP-5M/A, AP-10M/A
LEM-1, LEM-3
LEF-3, LEF-5 , LEF-10
LEF-10S
LEF-3C, LEF-5C, LEF-10C
A
B
FIXED NUMBER
FOR DISTANCE
BY ITEM
DIAMETER
mm
COMMUNICATION
DISTANCE
...m
3.4
1.6
2,000
1,000
900
800
700
600
500
400
300
200
100
90
80
70
60
50
40
30
20
1.4
1.2
1.0
0.8
0.65
0.5
3.9
5.2
6.8
7.8
10.4
17.4
20.9
26.2
34.0
36.7
225
1. On the graph;
Draw a line from IE-1AD(U) on point A 7.8, crossing the line B
at the point 0.8 to reach a point reading 225.
IE-1AD(U)
Distance
225 (m)
0.8
28
A
B
COMMUNICATION DISTANCE CALCULATION GRAPH
NOTES;
IE-1AD(U) [IF-DA] shows distance between IE-1AD(U) and IF-DA or other IE door station.
Video Intercoms are not included in the graph.
SYSTEM & MODELS
Communication Distance
The below graph is to assist you in determining the diameter of wires or communication distance required.
Example;
To obtain the communication distance for IE-1AD(U) system using 0.8 mm dia. wires;
108
COMMUNICATION DISTANCE
Comentarios a estos manuales