BLACK & WHITE VIDEO ENTRY SECURITY
MK-2MCD
• Optional audio door station at second entrance
• Infrared LED's projected on callers at 50cm in the darkness
Unit dimensions
Image view area
Specifications
180cm
90cm
65cm
45cm
50cm
130cm
220cm
90cm
50cm
180cm
MK-DAC, MK-DGC & MK-DBC
Max. pan-and-tilt view area:
90cm Vert., 180cm Horiz.
(approx.)
Power sourse DC 18V
Consumption MK-2MCD: (Max.) 750mA.
MK-2HCD: (Max.) 450mA.
MK-2SD: (Max.) 70mA.
Power supply PS-1820S, PS-1820UL
Calling Chime, audio & image, approx. 45 sec.
Communicarion Simultaneous with handsets, approx. 2-1/2 min.
Extend w/MONITOR. All call type voice calling,
common talk.
Door release AC 12V, 0.4A dry-closure contact(L, L).
Minimum illumination 1 Lux or less at 30cm distance
Scanning lines 525 lines
Video monitor 4 inch direct view flat CRT
Wiring 2 conductors to door.
4 conductors between inside stations
Distance Door to MK-2MCD 100m(1.0mma)
MK-2MCD to farthest sub 75m(1.0mma)
MK-2MCD to PS18 10m(1.0mma)
Wiring
RY-3DL
M
K-2M
CD
2
2
6
H
U
Selective door release &
OPTION feature button
When the system needs to control
two door releases selectively, install
the RY-3DL adaptor.The OPTION
button may be used, for example, to
turn the porch light, etc. For wiring,
6-pin connector is available as an
accessory. It plugs into the socket
on back of MK-2MCD unit, providing control outputs for Door Release and Option feature.
IER-2
88
120
83.5
29
RY-3DL
215
69
210
MK-2MCD, MK-2HCD MK-2SD
MK-DGC
114
19 3712.5
170
MK-DBC
92
115 12.5 1937
172
MK-DAC
98
130
47.5
44
MK-DH
35
98
130
83.5
MK-D
28
98
130
83.5
140
74
42
63
89
200
92
83.5
Electric door strike
Electric door strike
MK-2HCD
Sub master
station
MK-2HCD
Sub master
station
4
or
4
KC-32EU
Picture memory
unit
m
P.25
Electric door
strike
(locally available)
MK-D*
Audio door station
RY-3DL
Door release
adaptor
m
P.26
KAW-D
30kangled box
m
P.18
Lineup
MK-2SD
Audio sub
station
4
or
MK-2SD
Audio sub
station
Sub station
MKW-R
Surface mount box
for MK-DBC
*
Not available
in Europe
Comentarios a estos manuales