105
Accessories
TAR-3
External signaling relay
(1)
WH
BL
BK
RD
OG
OG
PWR
A1
S
S
A2
NP
MK-1GD
TAR-3
MK-DH
A
(–) (+)
A1
A2
+
–
W
U
(1) Bell, etc. PWR : Power source
WH : White BL : Blue BK : Black(-) RD : Red(+) OG : Orange
W : PS-0602D, PS-0602C
Wiring
104
41
62
Unit dimensions
IE chime tone
IE-8MD
MK-1GD
MK-2MCD
KC, KB series
AT-406
TB-SE(TC-M)
Used for
Allows integration of a
doorbell, etc. to intercom. The
device will be activated as long
as handset is ringing. When
the intercom is picked up, the
device will no longer be
activated.
Features
Power source 6V DC, supplied by PS-0602D, PS-0602C
Contact rating 0.3A, 240V AC.
1.0A, 24V DC.
Doorbell or buzzer must be AC operated
or DC mechanical type only.
Specifications (TAR-3)
Relay
MAW-B
Auxiliary light control relay
(1)
(2)
WH
BL
OG
RD
BK
PWR
bn = b1~b3
MAW-B
bn
E
KB-3MRD
+
–
N
(1) Porch light, etc. (2) Local switch
WH : White BL : Blue RD : Red(+) BK : Black(-) OG : Orange(2)
Wiring
MAW-B relay is used for
turning on an auxiliary light to
spotlight a caller at the
entrance.
The light is illuminated when
the residential call button is
pressed, and during visual
monitoring mode.
Features
Power source 24V DC.
Power supply PS-2420S, PS-2420UL of system.
Power consumption 2.5W max. 0.5W standby.
Relay contact rating Dry closure contact for incandescent light for
general lighting of less than 100W.
Specifications (MAW-B)
104
41
62
Unit dimensions
KB-3MRD, GF-BC(GF)
Used for
Auxiliary light power control
ACCESSORIES