Aiphone AI-900 Manual de usuario Pagina 14

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 13
__________________________ Aiphone AI-900 RTU Guide Ver 3.x ______________________________
Copyright © 1999- 2012 Intelli-Site
14
Substation groups must conform to settings in
the AI-900 driver. The default RTU (and
default driver settings) define the base station
number (the first station as programmed in the
AI-900) as Station No 10, that there are 16
stations per group and that there can be up to
6 groups. The reason that a grouping of 16
stations was chosen is because each AI-900
station card can accommodate up to 16
separate connections.
Note: The AI-900 is required to
be programmed in order to
recognize the groups and stations.
This programming is not
accomplished in Intelli-Site.
Refer to the AI-900 manual for
information on this.
The illustration below shows the AI900 tab in
the driver configuration settings page. To
access this tab, select the driver from Drivers
Services.exe and then choose the tab.
Based on the settings shown above, the
addressing for Substation groups will be as
shown in the table below:
Station
Group
Address
1st
Station
Address
Last
Station
Address
00
10
25
Vista de pagina 13